Product Category
Industry Standard
Position:Home>>About Rubadue wire>>Double Insulated Wires>>DXXA01FXX-3
DXXA01FXX-3 RUBADUE WIRE

Product Information
Size Range:
10 AWG - 40 AWG
Not all sizes listed in chart
Conductor:
Tin Plated Copper, Solid or Stranded (ASTM B-33/ASTM B-286)
Bare Copper and other conductors available
Bare Copper and other conductors available
Insulation:
FEP
Rating:
Temperature:155°C
Voltage: 600V
Applications:
Telecom / Electronic
Supplementary isolation applications
Compliances:
UL OBJT2 File No. E206198
UL / IEC 60950-1(Ed.2), Annex U
VDE License Nr. 6715: Class F
System approvals: UL 1446
RXT-2 Class F
TCA Class F
Other systems available upon request
RoHS Compliant
Tensile Strength: 3000 psi
Breakdown: Approx. 9000V
FEP is a Fluoropolymer compound with exceptional dielectric properties, heat resistance, chemical resistance, and flexibility. Commonly used in winding wires, UL AWM wires, and cable jacketing.
Insulated Wire Information:
Part Number | AWG | CONDUCTOR | NOMINAL O.D. | Weight LB/ KFT | ||
---|---|---|---|---|---|---|
Inches | MM | Inches | MM | |||
D10A37FXX-3 | 10(37/26) | 0.1070 | 2.718 | 0.1190 | 3.023 | 30.91 |
D12A01FXX-3 | 12 | 0.0808 | 2.052 | 0.0928 | 2.357 | 21.36 |
D12A19FXX-3 | 12(19/25) | 0.0862 | 2.189 | 0.0982 | 2.494 | 20.46 |
D14A01FXX-3 | 14 | 0.0641 | 1.628 | 0.0761 | 1.933 | 13.66 |
D14A19FXX-3 | 14(19/27) | 0.0679 | 1.725 | 0.0799 | 2.029 | 13.13 |
D16A01FXX-3 | 16 | 0.0508 | 1.290 | 0.0628 | 1.595 | 8.83 |
D16A19FXX-3 | 16(19/29) | 0.0539 | 1.369 | 0.0659 | 1.674 | 8.57 |
D18A01FXX-3 | 18 | 0.0403 | 1.024 | 0.0523 | 1.328 | 5.75 |
D18A19FXX-3 | 18(19/30) | 0.0476 | 1.209 | 0.0596 | 1.514 | 6.83 |
D20A01FXX-3 | 20 | 0.0320 | 0.813 | 0.0440 | 1.118 | 3.77 |
D20A19FXX-3 | 20(19/32) | 0.0385 | 0.978 | 0.0505 | 1.283 | 4.55 |
D22A01FXX-3 | 22 | 0.0253 | 0.643 | 0.0373 | 0.947 | 2.50 |
D22A19FXX-3 | 22(19/34) | 0.0295 | 0.749 | 0.0415 | 1.054 | 2.97 |
D24A01FXX-3 | 24 | 0.0201 | 0.511 | 0.0321 | 0.815 | 1.69 |
D24A19FXX-3 | 24(19/36) | 0.0242 | 0.615 | 0.0362 | 0.919 | 2.01 |
D26A01FXX-3 | 26 | 0.0159 | 0.404 | 0.0279 | 0.709 | 1.16 |
D26A19FXX-3 | 26(19/38) | 0.0190 | 0.483 | 0.0310 | 0.787 | 1.34 |
D28A01FXX-3 | 28 | 0.0126 | 0.320 | 0.0246 | 0.625 | 0.82 |
D28A19FXX-3 | 28(19/40) | 0.0152 | 0.386 | 0.0272 | 0.691 | 0.95 |
D30A01FXX-3 | 30 | 0.0100 | 0.254 | 0.0220 | 0.559 | 0.59 |
D32A01FXX-3 | 32 | 0.0080 | 0.203 | 0.0200 | 0.508 | 0.45 |
*ASTM B33 sets no standard for minimum resistance. This is only an indicator to investigate other aspects such as tin-thickness and tin coverage.