Silicone
Rubber Coated Fiberglass Sleeving Class 200 (-73°C to +200°C) (-100°F to
+392°F)
Description Varglas Silicone
Rubber Sleeving is produced by coating braided Fiberglas® with a
high-performance silicone rubber that is extremely flexible and exhibits
unusual toughness and abrasion resistance. In addition to having a Class
200°C rating, its brittle point of -73°C also suggests its use in a wide
range of applications requiring resistance to ternperature
extremes.
Specifications Varglas Silicone
Rubber Sleeving conforms to, and is listed on the qualified Products List
(QPL) for, MIL-l-3190/6, latest revision (Grade A); NEMA TF-1, Type 5; and
ASTM-D372.
Under the Component Program of Underwriters
Laboratories, Grade A Varglas Silicone Rubber is recognized for 200°C, 600
volt service and complies with VW-1 flammability requirements under UL
File #E63450. (VW-1 compliance of Grades B through C-3 is covered under UL
File #E53690.) The Canadian Standards Association certifies the use of
Grade A for 200°C, 600 volt service under CSA File #LR-58486 “HFS”.
Varglas Silicone Rubber is incorporated in systems work, per UL Safely
Standard 1446, to facilitate product acceptance by UL.
Applications Varglas Silicone
Rubber Sleeving is used in appliances, motors and generators as well as in
automotive, marine and aircraft electrical and electronic components such
as transformers, coils, relays, etc. where a 200°C thermal rating is
required. In addition to being well-suited as heavy duty insulation where
subjected to high heat, such as in die-casting and plastic molding,
Varglas Silicone Rubber Sleeving is also suitable for use in extremely
low-temperature environments such as high altitude and aerospace
applications.
Sizes AWG #24 through
2” l.D. Other sizes subject to inquiry
Standard Color Natural and
white. Other colors made to order.
Standard
Packaging Coils, spools or
36” lengths at manufacturer’s option, unless otherwise specified. There is
no cutting charge for 36” lengths, but lengths other than 36” are subject
to cutting charges.
Sizes over 1” l.D. are generally supplied in
36” lengths.
FibergIas® is a registered trademark of
Owens-Corning.
Typical Properties
| Property |
Procedure |
Performance |
| Physical |
| Tensile
Strength, Coating |
ASTM-D412 |
1500
psi |
| Ultimate
Elongation, Coating |
ASTM-D412 |
800% @
20°C |
| Hardness,
Coating |
ASTM-D2240 |
50
(Durometer) |
| Flexibility
and Toughness, Coating |
UL 1441
|
Passes
(Penetration test) |
| Chemical |
| Oil and
Solvent Resistance |
MIL-l-3190/6 |
Passes
(Excellent) |
| Water Vapor
Resistance |
MIL-l-3190/6 |
Passes
(Good) |
| Resistance
to Acids and Alkalies |
— |
Excellent |
| Resistance
to the Elements |
— |
Unaffected
by sunlight and weather. |
| Compatibility |
UL 1446
|
Good.
Compatible with most potting compounds and varnishes. |
| Electrical |
| Dielectric
Strength after 48/23/50: |
|
|
NEMA TF -
1 |
8000v min.
avg., 6000v min. indiv. |
|
|
NEMA TF -
1 |
4000v min.
avg., 2500v min. indiv. |
|
|
NEMA TF -
1 |
2500v min.
avg., 1500v min. indiv. |
|
|
NEMA TF -
1 |
1500v min.
avg., 800v min. indiv. |
|
|
NEMA TF -
1 |
No voltage
guarantee. |
| Dielectric
Strength after 96/23/96: |
|
|
NEMA TF -
1 |
80% of
Original Value. |
| Hydrolytic
Stability after 336 hrs. @ 70°C over Constant Water Reflux |
MIL-I-3190/6 |
5000 volts
min. avg. |
| Thermal |
| Thermal
Endurance |
MIL-l-3190/6 & UL 1441 |
Class 200°C
(H) |
| Brittleness
Temperature |
ASTM-D350 |
-
73°C |
| Flame
Resistance |
UL 1441
|
Passes
(VW-1) |
| ASTM-D350,
Method B |
Passes |
| NEMA
TF-1 |
Passes |
| MIL-l-3190/6, Method B |
Passes |
| Pushback
|
MIL-l-3190/6 |
No cracks
or ruptures. 6000 volts mm. avg. breakdown
strength. |
Note:
Information contained here is precise and reliable. However, being unique,
each end-use should be evaluated to satisfy its specific
requirements.
|
|
|