Fluoroelastomer Coated Fiberglass Sleeving Class 220 (-70°to
+220°C) (-94° to +428°F)
Description Varglas Viton®
231 Sleeving is a braided Fiberglas®/modified Viton® cornposite with
exceptional physical and electrical properties. It has excellent abrasion
and cut-through resistance and offers improved flexibility throughout a
wide operating temperature range. Its resistance to solvents, both
aromatic and aliphatic; fuels, including JP-5; and oils, including
Skydrol; place this fluoroelastomer above other available polymer-coated
fiberglass braids.
Specifications Varglas Viton®
231 Sleeving conforms to, and is listed on the Qualified Products List
(QPL) for, MIL-l-3190/7, latest revision (Grade A), and exceeds the
requirements of NEMA TF-1 and ASTM-D372.
Under the component
program of Underwriters Laboratories, Varglas Viton® 231 Sleeving complies
with VW-1 flammability requirements under UL File #E53690. It is
incorporated in systems work, per UL Safety Standard 1446, to facilitate
product acceptance by UL.
Applications Varglas Viton®
231 Sleeving is used in DC generators and motors to reduce arcing problems
and elsewhere when the need to maintain a silicone-free environment is
important. Its flame resistance and excellent resistance to abrasion make
it ideally suited for the insulation of leads and connections of critical
electrical components as well as for wire harnesses in areas where
continuous operating temperatures run as high as 220°C. Varglas Viton®231
is also used in transformers where resistance to high impingement velocity
oils is required and, generally, where better solvent and oil resistance
is needed.
Sizes AWG #24 through
3” I.D. Other sizes subject to inquiry.
Standard Color Black, white and
natural.
Standard
Packaging Coils, spools or
36” lengths at manufacturer’s option, unless otherwise specified. There is
no cutting charge for 36” lengths, but lengths other than 36” are subject
to cutting charges.
Sizes over 1” l.D. are generally supplied in
36” lengths.
FibergIas® is a
registered trademark of Owens-Corning. Viton® is a registered trademark
of the DuPont Company.
Typical Properties
| Property |
Procedure |
Performance |
| Physical |
| Tensile
Strength, Coating |
ASTM-D412 |
200 psi @
24°C; 600 psi @ 149°C |
| Ultimate
Elongation, Coating |
ASTM-D412 |
150% @
24°C; 75% @ 149°C |
| Hardness,
Coating |
ASTM-D2240 |
80
(Durometer, Shore A) |
| Flexibility
and Toughness, Coating |
UL 1441
|
Passes
(Penetration Test) |
| Chemical |
| Resistance
to Atmospheric Oxidation, Sun and Water |
— |
Excellent |
| Resistance
to Ozone Concentrations |
— |
Unaffected
at levels as high as 100 ppm |
| Fungus
Resistance |
MlL-E-5272 |
Passes |
| Solvent*,
Chemical and Oil Resistance |
MIL-I-3190/7 |
Passes
(Excellent) |
| Electrical |
| Dielectric
Strength after 48/23/50: |
|
|
NEMA TF -
1 |
8000v min.
avg., 5000v min. indiv. |
|
|
NEMA TF -
1 |
4000v min.
avg., 2500v min. indiv. |
|
|
NEMA TF -
1 |
2500v min.
avg., 1500v min. indiv. |
| Dielectric
Strength after 96/23/96: |
|
|
NEMA TF -
1 |
80% of
Original Value. |
| Hydrolytic
Stability after 336 hrs. @ 70°C over Constant Water Reflux |
MIL-I-3190/7 |
6000 volts
min. avg. |
| Thermal |
| Thermal
Endurance |
MIL-l-3190/7 |
Class 220°C
(R) |
| Brittleness
Temperature |
ASTM-D350 |
-
73°C |
| Flame
Resistance |
UL 1441
|
Passes
(VW-1) |
| ASTM-D350 |
Passes |
| NEMA
TF-1 |
Passes |
| MIL-l-3190/7, Method A |
Passes |
| Oxygen
Index |
— |
85% |
| Radiation
Resistance |
DuPont
Bulletin E-37758 |
Up to
106 rads with little or no effect on physical
properties |
| Smoke
Density |
Rohm &
Haas SD Test XP-2 |
Passes;
test requires a minimum SDR4 of
15%. |
*
Do not use Ketone type solvents as a cleaning liquid for Varglas
Viton® 231. We recommend using V.M. & P.
Naphtha.
Note. Information contained here is precise and reliable
However, being unique. each end-use should be evaluated to satisty its
specific requirements
|
|
|